Overview Options Specifications Images

Photometry

HP-4 WW-D Photometry

HP-4 WW-R
3500K, Very High Output (V)
Total lumens: 1816
Lumens per foot: 454
Lumens per watt: 91.7

Refer to the tech sheet to calculate lumens for the desired CCT or CRI.

Wall Wash Recessed Specifications

CONSTRUCTION

Precision-cut 6061-T6 extruded aluminum body. Internal joiner system, plug-together wiring, standard. Housing is powder coated.

REFLECTORS

The standard semi-specular aluminum (SSA) kicker (K) reflector delivers light high on the vertical surface. The kicker reflector can be easily removed for open distribution (FO).

ENDCAPS

Flat endcaps add 0.05" to each end of luminaire.

REFELECTOR

94% reflective semi-specular reflector (94SS) provides reflectivity and glare control. The standard kicker (K) reflector delivers light high on the vertical surface. The kicker reflector is easily removed for open distribution (FO).

DIFFUSER

Luminaires are standard with frosted lenses. All lenses are UV-stabilized and impact resistant virgin acrylic. Frosted lenses are 0.080" thick. 12' maximum lens length.

LIGHT OUTPUT

Four lumen packages available, Standard Output (S), Boosted Standard Output (B), High Output (H), and Very High Output (V). A separate chart summarizes lumen distribution and wattage. Light engines are replaceable.

LUMEN MAINTENANCE

90% of initial light output (L90) at 100,000+ hours; 70% of initial light output (L70) at 200,000+ hours.

DRIVER

Replaceable 120V/277V Constant Current Reduction dimming driver standard. Can be wired dimming or non-dimming. 0-10V dimming controls with a range of 10%- 100%. Dimming to 1% available; consult factory. Driver is fully accessible from below the ceiling. Power Factor: ≥ 0.9. Total Harmonic Distortion (THD) < 20%. Expected driver lifetime: 100,000 hours.

LUTRON DRIVER OPTIONS

Lut3W-3-wire, LutESEcoSystem, Lut2W-2-wire.

Protected by one or more US Patents: 8915613; D702,391; D702,390; D700,732

 
ELECTRICAL

Optional emergency to generator/inverter wiring, internal generator transfer switch, nightlight wiring, step-dimming driver, backup battery. Factory-choice lowprofile backup battery available. 8' minimum fixture length for low profile battery pack. Bodine BSL722 battery pack also available; 4' minimum fixture length. Backup battery delivers 1400 lumens. One 4' section will be illuminated in emergency mode.

MOUNTING

Standard bracket design works with most lay-in ceiling types. Brackets secure luminaire to the ceiling grid from above. Tie-in T-Bar brackets. Connect luminaire to T-Bar for securing to structure. Consult local codes for tie-wire recommendations.

FEED

Standard with one 18-gauge/5-conductor single-circuit feed. 14-gauge feed used when fixture current exceeds 5 amps. Optional 6’ flex conduit whips available.

LENGTHS

Any length, 2-foot minimum, in increments down to 1/16th-inch (± 1/32"). 12-foot maximum section length.

LABELS

Luminaire and electrical components are ETL-listed conforming to UL 1598 in the U.S.A. and CAN/CSA C22.2 No. 250.0 in Canada. In accordance with NEC Code 410.73 (G), this luminaire contains an internal driver disconnect. Damp Location. Finelite products use electronic components that are RoHS compliant, and the mechanical components of the luminaire have been verified to not knowingly contain any restricted substances listed per RoHS Directive 2011/65/EU.

WEIGHT

2.9 lb/ft.

WARRANTY

10-year performance-based warranty on all standard components. Optional accessories such as emergency battery packs are covered by their individual manufacturer warranties.

TUNABLE WHITE

Refer to the tunable white tech sheet for more information.