Finelite
Product ShortcutsProduct Shortcuts|Media Center|Agent Login|Contact|Home
ID
ID
D
D
WW-D
WW-D
I
I
WM-ID
WM-ID
WM-D
WM-D
WM-I
WM-I
RECESSED
RECESSED
WW-RECESSED
WW-RECESSED
SM
SM
WW-SM
WW-SM
WW-AM
WW-AM
Overview Options Specifications Images

Photometry

HP-2 R Photometry

HP-2 R
3500K, Very High Output (V)
Total lumens: 3287
Lumens per foot: 822
Lumens per watt: 89

HP-2 RG Photometry

HP-2 RG
3500K, Very High Output (V)
Total lumens: 2907
Lumens per foot: 727
Lumens per watt: 79

Refer to the tech sheet to calculate lumens for the desired CCT or CRI.

Recessed Specifications

CONSTRUCTION

Precision-cut 6061-T6 extruded aluminum body. Internal joiner system, plug-together wiring, standard. Housing is powder coated.

ENDCAPS

Flat endcaps at each end of run add 1/16" to overall length. Drop Down Lens Illuminated Endcap (DE) includes diffuse element to continue luminance of drop lens.

MITERED CORNER

Illuminated 90° corners in a single plane, Flush downlight diffuser (standard), or White Cross Blade Baffle (optional). Custom angles are available (90° minimum on inside corners), contact factory. 90 degree corners not available with Hollowed Ellipse Louver (LHE) or Hex Louver (LHC). White Cross Blade Baffle (WCB) is not available with custom angles. Available in 90 degrees only.

REFLECTORS

Die-formed 24-gauge cold-rolled steel reflectors are finished in 96 LG high reflectance matte white powder coat paint.

DOWNLIGHT OPTION

12' maximum diffuser length. Flush frost white snap-in diffuser standard, 73% transmissive, 99% diffusion. Internal secondary diffusers at corners ensure visually seamless, uniform, continuous illumination. Available with Flush (F), 1" Drop Down Lens (DL), White Cross Blade Baffle (WCB - currently not advisable for drywall) 2, Hollowed Ellipse Louver (LHE), Hex Louver (LHC), and Regressed downlight diffusers (RG). 1" Drop Down Lens made of highly efficient acrylic.

LIGHT OUTPUT

Four lumen packages available, Standard (S), Boosted Standard (B), High (H), and Very High (V). A separate chart summarizes lumen distribution and wattage. Light engines are replaceable.

LUMEN MAINTENANCE

90% of initial light output (L90) at 100,000+ hours; 70% of initial light output (L70) at 200,000+ hours.

DRIVER

Replaceable 120V/277V and 347V Constant Current Reduction dimming driver standard. Can be wired dimming or non-dimming. 0-10V dimming controls with a range of 10%- 100%. Dimming to 1% available; consult factory. Driver is fully accessible from below the ceiling. Power Factor: ≥0.9. Total Harmonic Distortion (THD): <20%. Expected driver lifetime: 100,000 hours. Dali driver also available; Contact factory.

LUTRON DRIVER OPTIONS

LUTES1 (Hi-lume 1% EcoSystem with Soft-On, Fade to Black dimming (LDE1 series)); LUTES5 (5-Series 5% EcoSystem (LDE5 Series)), LUT2W (Hi-lume 1% 2-wire, 120V forward phase dimming (LTEA series)); Contact factory for availability of discontinued Lutron drivers, L3DA-3-wire and L3DA EcoSystem.

Protected by one or more US Patents: 8915613; D702,391; D702,390; D700,732; D727,554 S; D727,550 S, D727,551 S

 
ELECTRICAL

Optional emergency to generator/inverter wiring, internal generator transfer switch, nightlight wiring, step-dimming driver, backup battery. Chicago Plenum Option. Factory-choice low-profile backup battery available. 8' minimum luminaire length for low profile battery pack. Backup batteries deliver 1000 lumens. Half of a 4' section will be illuminated in emergency mode.
 

INTEGRATED SENSORS

Integrated PIR (Passive Infrared) occupancy and/or daylight sensors available with Flush, White Cross Blade Baffle, and Regressed downlight diffusers. 3' minimum luminaire length. Refer to Occupancy Sensor and Daylight Sensor tech sheets for more info.
 

MOUNTING

Standard bracket design works with most lay-in ceiling types. Brackets secure luminaire to the ceiling grid from above. Tie-in T-Bar brackets connect the luminaire to the T-Bar for securing to structure. Consult local codes for tie-wire recommendations.
 

FINISHES

Finelite Signal White powder coat standard.
 

FEED

Standard with one 18-gauge/5-conductor single-circuit feed. 14-gauge feed used when luminaire current exceeds 5 amps. Optional 6' flex conduit whips available.
 

LENGTHS

Any length, 2' minimum, in increments down to 1/16" (± 1/32"). 12' maximum section length. Hollowed Ellipse Louver (LHE), Hex Louver (LHC), and White Cross Blade Baffle (WCB) are available in 1' increments.

LABELS

Fixture and electrical components are ETL-listed conforming to UL 1598 in the U.S.A. and CAN/CSA C22.2 No. 250.0 in Canada. In accordance with NEC Code 410.130 (G), this luminaire contains an internal driver disconnect. Finelite products use electronic components that are RoHS compliant, and the mechanical components of the luminaire have been verified to not knowingly contain any restricted substances listed per RoHS Directive 2011/65/EU.
 

WEIGHT

2.3 lb/ft.
 

WARRANTY

10-year performance-based warranty on all standard components. Optional accessories such as emergency battery packs are covered by their individual manufacturer warranties.
 

Finelite Home LinkedInFacebookTwitterYouTubePinterestInstagram A brand of Legrand

© Finelite, Inc. All rights reserved.    Contact Us  |  Privacy Policy  |  Sales Terms and Conditions  |  Site Map